UPS10~20KVA
Model Number:UPS10~20KVA
Model Number:
Added:2019-03-05
Views:
Telephone:0755-23287132
Keywords:
Next Previous

Details

Characteristic

Energy storage inverters are connected between mains and critical loads, such as computers, to provide high-quality power to the loads. The energy storage inverter has the following advantages:

l Improve power supply quality

Energy storage inverter through the internal voltage and frequency regulator, so that its output is not affected by the changes in its input power supply.

l Power loss protection

If the input power is cut off, the energy storage inverter is powered by the battery, and the load power supply is not interrupted.

Design idea

1.The energy storage inverter is composed of power input (main and bypass), rectifier /PFC, charger, inverter, bypass, battery, and output modules.

2.When the mains power is normal, the rectifier starts and the charger charges the battery. The output voltage is the by-pass voltage through which the mains power supplies the load.

3.When the mains power is abnormal, the battery voltage is fed into the inverter circuit after being boosted by the rectifier /PFC circuit, and the pure sinusoidal ac is output through the inverter circuit, which is provided to the load through the electronic conversion switch.

4.After the mains power is restored to normal, the energy storage inverter automatically switches back to normal mode from the battery mode, and the mains power supplies the load through the bypass.

Operational mode

Energy storage inverter is an online energy storage inverter system with the following operation modes:

l Normal mode

l Battery Mode

Normal mode

As shown in the figure, when the energy storage inverter works in normal mode, the power required by the load is provided by the mains input directly through the bypass static switch. If the rectifier is normal, the built-in charger charges the battery.

Battery Mode

As shown in the figure, when the mains power fails or the voltage exceeds the range, the rectifier and the built-in charger stop running, and the battery supplies power to the load through the inverter. The running indicator light is on, accompanied by a buzzer warning that the energy storage inverter is in battery mode.

储能逆变器功率(kVA)

额定电流(A)

母线柱头螺栓/螺母规格

最大输入电流1

满载时输出/旁路电流2

最低电池电压时的电池放电电流3

输入/电池/输出/旁路/PE

电缆

推荐力矩(Nm)

380V

400V

415V

50kVA

159

121

116

111

293

M10

22

100kVA

200

152

145

139

366

M10

22

150kVA

319

242

232

222

585

M12/M12/M12/M12/M10

39/39/39/39/22

200kVA

399

303

290

278

731

M12/M12/M12/M12/M10

39/39/39/39/22

250kVA

499

378

362

347

951

M12/M12/M12/M12/M10

39/39/39/39/22

HOME
About us
Company profile
Corporate culture
Team demeanor
Organization chart
Products
Smart Power
Energy storage
Technical support
News Center
Join us
Campus recruitment
Social recruitment
Contact us

Contact us

  • Address:Building 8, factory building, fuan no.2 industrial city, dayang development zone, fuhai street, baoan district, shenzhen  
  • Telephone:0755-23287132  
  • Fax:0755-23287133
  • Mobile Phone:13798502745  
  • Email:sales@tiancipower.com  
Copyright © 2020- Shenzhen Tianci technology co. LTD   All Rights Reserved.
Legal notices   |   Privacy protection   |   Contact us   |   Site map   丨    Powered by 400301.com